Test PAHs or Benzo[a]Pyrene using Sitelab Analyzers
 
 
Coal tars contain high concentrations of polycyclic aromatic hydrocarbons (PAHs) and are found in reclaimed asphalts, pavement sealcoating products, creosotes used on utility poles and railroad ties and soils contaminated from Manufactured Gas Plant (MGP) sites.
 
Benzo[a]Pyrene (BaP) is very toxic compound and is regulated in the UK's asphalt industry, where coal tars were once used to make asphalt pavement long ago.  Today, the tar is milled from roads and highways and mixed with new asphalt binder for resuse.  BaP concentrations in reclaimed or recycled asphalts must be below 50 ppm mg/Kg to meet the UK's regulatory waste limits.
 
Sitelab's UVF-500D and UVF-Trilogy fluorescence analyzers are both suitable for testing PAHs or BaP in coal tar contaminants and are highly sensitive to these compounds, with detection limits in the low ppb range.
 
Sample test kits and calibration standards available are compitable with both models.  Samples are extracted in methanol solvent for analysis performed on-site or in the laboratory.  These devices are is easy to use.  No training or maintenance is required.

Download: RECLAIMED ASPHALT PERFORMANCE STUDY
See how Sitelab's portable UVF-500D and UVF-Trilogy analyzers compare to certified laboratory GC/MS methods testing PAHs and Benzo[a]Pyrene.
 

Products Used for Analysis:
Click images to enlarge
Download Sitelab SOPs:
  
Click test procedures below...
 
Benzo[a]Pyrene in Asphalt
Sample Test Procedures:

 
UVF-500D ANALYZER
 
UVF-TRILOGY ANALYZER
 


 
  Click test procedures below...
    
PAHs in Coal Tar Contaminants
Sample Test Procedures:

  
UVF-500D ANALYZER
 
UVF-TRILOGY ANALYZER
 
   
   
SAMPLE TEST KIT
For asphalt, soil or sediment,
p/n EXTR010-20-PAHS
UVF-500D
Handheld Analyzer,
p/n 50200 
UVF-TRILOGY
Benchtop Analyzer,
p/n 7200-004-PAHS
   

 

ADEPT UK, Reclaimed Asphalt Regulations:
 

Guidelines specified by the Association of Directors of Environment, Economy, Planning & Transport (ADEPT), for managing reclaimed asphalt in the United Kingdom, now permit UV flourescence-based instruments to be used for PAH screening purposes.
 
Sitelab's methods, products and procedures were developed to meet ADEPT's specifications as a Rapid Monitoring Technique (RMT) screening method.  Use Sitelab's portable UVF analyzers to determine if asphalts contain Benzo[a]Pyrene above or below ADEPT's 50 ppm and 25 ppm action limits.  For more details about ADEPT and UK Environment Agency's coal tar regulations, see links below:

ADEPT MANAGING RECLAIMED ASPHALT GUIDELINES 2024
 
ENVIRONMENT AGENCY WM3 WASTE REGULATIONS
 
 
 
Benzo[a]Pyrene Standards,
Part No. CAL-BAP-COALTAR
 


Click to enlarge

BaP Calibration Instructions:

  
UVF-500D ANALYZER
 
UVF-TRILOGY ANALYZER

 
 
Test PAHs in Coal Tar Contaminated Soils & Other Samples:
 

Sitelab's UVF-500D and UVF-Trilogy analyzers can be calibrated to measure PAHs - as the sum of EPA's 16 regulated compounds - using Sitelab PAH calibration kits available. 

These products contain ready-to-use, certified standards in methanol, supplied with a 6-month expiration date and Certificate of Analysis.  See calibration instructions for details.

Use for coal tar sites where Total PAH analysis is required.  Samples are prepared using the same test kit used for Benzo[a]Pyrene analysis, part no. EXTR010-20-PAHS, and is used with both UVF analyzers.  

Results correlate well to laboratory GC/MS methods.  Ideal for screening PAH concentrations in parking lot sealcoats to meet the 1,000 mg/Kg or 10,000 mg/Kg PAH action limits, where regulated.  See link below for details:
 
 
 
     

Sitelab PAH Calibration Kits
 


 Click to enlarge

PAH Calibration Instructions:

  
UVF-500D ANALYZER
Using Part No. CAL-061M-500D
 
UVF-TRILOGY ANALYZER

Using Part No. CAL-060M
 
 
CONTACT SITELAB
For pricing or if you need help deciding which instrument is most suitable for your application 
  

 
See Method 8670 (Draft) for additional PAH performance data:




See Sitelab's UVF-Trilogy, UVF-500D and other products available:

 

Learn more about this topic:



 

 Welcome to site-lab.com!   HOME   I   WHAT'S NEW   I   PRODUCTS & SERVICES   I  APPLICATIONS   UV FLUORESCENCE   I  TEST PROCEDURES   I  CONTACT US

© 2025  Sitelab Corporation   USA   All Rights Reserved      site-lab.com      Sitelabcorp.com     SitelabCorporation.com