UVF-Trilogy Calibration Kits Available:
 
Sitelab's standards are made from Certified Reference Materials (CRMs) and are used to perform calibration checks for quality control or to recalibrate the analyzer, if necessary.  These products are specially formulated to ensure accurate measurement and produce results that correlate well to U.S. EPA and other regulatory lab methods. 

Each kit includes 5 calibration standards, plus 2 reference standards and supplies used as a backup to prepare new calibration standards, if necessary.  The calibration standards are reusable and supplied with a 6-month expiration date.  Copy of Certificate of Analysis, MSDS and calibration instructions are included. 

These products are easy to use and are always in stock.  Available in methanol or hexane solvents.  Scroll down this page to see these and other calibration products available.   

  
 
 

GRO 

 
GASOLINE RANGE ORGANIC HYDROCARBONS
Part No. CAL-025MIn Methanol for Soil Analysis
Part No. CAL-025HIn Hexane for Water Analysis


Use to detect BTEX and other volatile petroleum hydrocarbons in the C6 to C10 gasoline range.  Common applications include gasolines, jet fuels, fuel oils and other light-refined hydrocarbons. 
Minimum detection limit = 0.5 ppm.
  Use with Sitelab's UVF-Trilogy
GRO UV fluorescence module

Click images to enlarge:


 
Use for soil and water analysis!
Download: GRO CALIBRATION INSTRUCTIONS
 
Go To: GRO APPLICATIONS
 
 
  EDRO 

 
EXTENDED DIESEL RANGE HYDROCARBONS
Part No. CAL-042MIn Methanol for Soil Analysis
Part No. CAL-042HIn Hexane for Water Analysis


Use to detect petroleum hydrocarbons in the C10 to C36 diesel and oil range.  Common applications include heating oils, diesel fuel, waste oils, lube oils, crude oils and many other types of petroleum. 
Minimum detection limit = 0.1 ppm.
 
  Use with Sitelab's UVF-Trilogy
EDRO UV fluorescence module

Click images to enlarge:

  
Use for soil and water analysis!
 
Download: EDRO CALIBRATION INSTRUCTIONS
 
Go To: EDRO APPLICATIONS
 
 
  PAHS

 
POLYCYCLIC AROMATIC HYDROCARBONS
Part No. CAL-060MIn Methanol for Soil Analysis
Part No. CAL-060HIn Hexane for Water Analysis


Use to detect Target PAHs as the sum of U.S. EPA's priority pollutant compounds in fuel oils, waste oils, crude oils, creosote, coal ash, coal tar, asphalt and other contaminants.  Or use for hydrocarbon fingerprinting testing Total PAHs and Heavy PAHs with the EDRO and TPHOIL modules.  Minimum detection limit = 0.05 ppm.
     
  Use with Sitelab's UVF-Trilogy
PAHS UV fluorescence module

Click images to enlarge:


  
Use for soil and water analysis!
 
Download: PAH CALIBRATION INSTRUCTIONS
Go To: PAH APPLICATIONS
 
 
 
  TPH OIL 

 

TPH OIL RANGE hYDROCARBONS
Part No. CAL-057MIn Methanol for Soil Analysis
Part No. CAL-057HIn Hexane for Water Analysis

 
Use to detect Total Petroleum Hydrocarbons in the C15 to C50 "oil and grease" range.  This test compares well to EPA Method 1664 and other Gravimetric or GC methods for detecting crude oils and heavy fuel oils.
Minimum detection limit = 0.5 ppm.  

 
   
  Use with Sitelab's UVF-Trilogy
TPHOIL UV fluorescence module

Click images to enlarge:
 
 
Use for soil and water analysis!
 S

Download: TPH OIL CALIBRATION INSTRUCTIONS
 
Go To: TPH OIL APPLICATIONS
 
 
  TPH OIL, High 

 
 
TPH OIL RANGE, HIGH CONCENTRATIONS
Part No. CAL-056MIn Methanol for Soil Analysis
Part No. CAL-056HIn Hexane for Water Analysis


Same as Sitelab's CAL-057M and CAL-056H calibration kits, but at higher concentrations up to 100 ppm, requiring no or fewer dilutions needed for analysis.  Minimum detection limit = 5 ppm.

 
  Use with Sitelab's UVF-Trilogy
TPHOIL UV fluorescence module

Click images to enlarge:

   
Use for soil and water analysis
S
 
Download: TPH OIL CALIBRATION INSTRUCTIONS Go To: TPH OIL APPLICATIONS
  
 
 
Calibration Kits for Older Sitelab UVF-3100 Models:
   
 
 

 

 
These products look and function identical to Sitelab's UVF-Trilogy calibration kits.  Includes a Certificate of Analysis, MSDS and instructions.  Calibration standards are reusable and supplied with a 6-month expiration date.  Available in methanol for soil analysis or hexane for water analysis.

Sitelab's UVF-3100A and UVF-3100D models were discontinued in 2018 after 20 years in production and replaced by the newer UVF-Trilogy instrument.
 

CONTACT US FOR PRICES OR SALES QUOTE

To purchase UVF-3100 calibration kits and order sample test kit supplies.  We service these instruments too and can calibrate the analyzer for you.

     

  GRO Calibration Kits:
CAL-025M-3100 In Methanol
CAL-025H-3100 In Hexane

EDRO Calibration Kits:
CAL-042M-3100 In Methanol
CAL-042H-3100 In Hexane

PAH Calibration Kits:
CAL-060M-3100 In Methanol
CAL-060H-3100 In Hexane

TPH-Oil Calibration Kits:
CAL-057M-3100 In Methanol
CAL-057H-3100 In Hexane
 
 
 
Calibration Standards for Oil-in-Water (OIW) Monitors
 
 


 
Sitelab provides certified reference standards used to calibrate TD-4100 and TD-120 oil in water monitors manufactured by Turner Designs Hydrocarbons Instruments, Inc. (TDHI), now part of Benchmark Measurement Solutions located in Canada.

The standards are used to calibrate when the source oil is unknown or not available and ensure accurate and repeatable measurements. 

These instruments use flourescence to measure water continuously 24/7 without the use of solvent extraction.  Applications include produced water, cooling water, leak detection, groundwater treatment and many others.   

Products are supplied in methanol and have a 6-month expiration date.  Includes MSDS and Certificate of Analysis with instructions.
   
 
   
OILINWATERMONITORS.COM

TD-4100 XDC Standards:
CAL-TPH-XDC200 TPH in Water
CAL-GRO-XDC200 GRO in Water

TD-4100 XD Standards:
CAL-TPH-XD2000 TPH in Water

TD-120 Standards:
CAL-TPH-TD120 TPH in Water
CAL-GRO-TD120 GRO in Water
    
 
 
Shipping Requirements for Dangerous Goods
 
  Sitelab's calibration products contain methanol or hexane solvents which are flammable, hazardous materials.  We use Federal Express to ship these products worldwide, packaged in a small 12"x10"x6" box and weigh 1 to 2 lbs, depending on the quantity or product ordered. 

Fedex prohibits the shipment of these products to some countries.  Please visit the FEDEX WEBSITE for a list of countries served and prohibited.

We do not ship these products with DHL, UPS or other carriers.  Only Fedex International Priority Service can be used for shipments outside the United States.  Typical delivery is 2 to 5 days depending on location. 
 

Copies of Sitelab's Material Safety Data Sheets (MSDS) included with each product are available upon request.

CONTACT US to order, get pricing or have questions about which products are most suitable for your application.
         
 
 
CLICK BELOW FOR ALL SITELAB'S PRODUCTS, TEST PROCEDURES AND APPLICATIONS
  

 
 


  

 

 
  See example copies of COAs included with UVF-Trilogy Calibration Kits


  
 


 Welcome to site-lab.com!    HOME   I   WHAT'S NEW   I   PRODUCTS & SERVICES   I  APPLICATIONS   UV FLUORESCENCE   I  TEST PROCEDURES   I  CONTACT US

© 2024  Sitelab Corporation   USA   All Rights Reserved      site-lab.com      Sitelabcorp.com     SitelabCorporation.com